Directional Valve Check Valve |
QCV10-21 126.81 KB
2 way valve cavity series 255.22 KB
|
QCV10-21 = Check valve =
SYMBOLS:
ISO:
DESCRIPTION:
A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.
The QCV10-21 allows flow passage from ➁ to ➀, while blocking flow from ➀ to ➁. The cartridge has a fully guided check which is spring-biased closed until sufficient pressure is applied at ➁ to open to ➀
Operating Pressure (bar) |
Proof Pressure (bar) | Flow | Internal Leakage (cc/min) |
User Temperature(0C) | Operation Voltage |
210 | 420 | 56 lpm/15 gpm | 0.25 cc/min (First remove inside air) |
-400~ 120 | ± 15% voltage |
FEATURES
.100% full inspection for all products.
.Standard product life tested for million cycles.
.1000-hour salt-spray anti-corrosion protection tested.
.Raw material, oil, electroplating, etc. in manufacturing process with RoHS compliance.
.All coils tested by third party notarization inspection & CE certified.
.Heat Treatment on spool, poppet, cage for long life and low leakage.
.Coil rated for continuous duty
.Customized coil voltages and terminations
.Cartridges are customized.
.Manual override option.
.Multi industrial applications.
.Compact size.
.Coil mold design with sufficient demands
RATINGS
Operating Pressure: 210 bar (3000 psi)
Proof Pressure: 420 bar (6090 psi)
Flow: 56 lpm (15 gpm)
Internal Leakage: 0.25 cc/minute
User Temperature: -40° to 120°C (-40° to 248°F) with Buna seals;
User Temperature: -26° to 204°C (-15° to 400°F) with Fluorocarbon seals
Filtration: With S: 100 mesh (149 micron)
Operation Voltage: ±15% voltage
Cavity: Q10-2; See page Q10-2
Related products: